Factorio sr latch nuclear. - Because of fixed latch, does not require priming.



Factorio sr latch nuclear One of the obvious applications is using this contraption to turn on steam generator reserve when accumulators' energy level is 1% or less, and turn them off Feb 1, 2017 · - An SR latch to trigger activation (activate when charge goes below x and deactivate when it goes above y) - always charges itself first before connecting to the main network - powers up to charge itself when stored electricity is low (using an SR latch and without connecting to the main network) - powers its own inserters and small pumps Aug 31, 2020 · anyway, basically what I need is a SR latch. History. I know we can do these with existing combinators, I do it all the time. but SR latch is complex for this simple problem. Jun 1, 2019 · All-Signal SR Latch Memory (SET/4tick, RESET/3tick) This board is to show, discuss and archive useful combinator- and logic-creations. One of the obvious applications is using this contraption to turn on steam generator reserve when accumulators' energy level is 1% or less, and turn them off Jul 12, 2016 · That's an interesting approach. This board is to show, discuss and archive useful combinator- and logic-creations. Converting a varying signal into a rate of change signal can be done with an arithmetic combinator and some wiring:  · Factorio Forums. So you can't connect 400 heat pipes to the nuclear reactor to measure when it reaches 900°C. 18 posts • Page 1 of 1. But then if you wanted to adjust the resources you just adjust the value in the logistics group and it Feb 16, 2021 · Factorio CheatSheet says that 4 cores loss-less need 40 steam tanks. May 7, 2017 · Make a belt loop SR latch with the read step outputting a pulse instead of holding. One of the obvious applications is using this contraption to turn on steam generator reserve when accumulators' energy level is 1% or less, and turn them off Oct 30, 2024 · This board is to show, discuss and archive useful combinator- and logic-creations. Wiki; Active topics; FAQ; Board index. Sep 13, 2019 · I have searched over the requests, and haven't found this one. Still a pain in the butt every time, though. ↳ Discover Factorio Wiki; ↳ Discover Others  · A Set-Reset Latch is a circuit network item, that starts emitting a signal when a "set" event (logical condition) occurs, and stops emitting the signal only when a "reset" event occurs. Please provide if possible always a blueprint of your creation. Jun 2, 2019 · - Changed latch mechanism to automatically reset in case of undefined state (undefined state lead to fast blinking lights and not starting). I use an SR latch (I put a generic design for an SR latch up at this link). It has somewhat complicated dynamics when you start to look at corner cases, but the basic idea is it has a "set" input and a "reset" input. A Set-Reset Latch is a circuit network item, that starts emitting a signal when a &quot;set&qu  · A Set-Reset Latch is a circuit network item, that starts emitting a signal when a "set" event (logical condition) occurs, and stops emitting the signal only when a "reset" event occurs. You don't need to micromanage everything through combinators. Jun 3, 2019 · I recently created an all signal SR Latch after being inspired by some of the great combinator creations here. The reactor will overheat way before the heat travels that far. When can I (safely) start with nuclear power? JasonCurnow Inserter Posts: 24 Joined: Wed Jan 03, 2018 4:44 am. In this case your accumulator charge decays slowly giving you an opportunity to make a frame for say 50-90% of accu charge and turn steam on if below 50% Dec 12, 2024 · This board is to show, discuss and archive useful combinator- and logic-creations. 2 days ago · Page "Nuclear power" has been recommended for clean-up. This design you are trying to implement is working fine if you want to implement steam backup for solar power. The common example in Factorio is May 7, 2017 · The SR-latch, giving a setpoint hysteresis, makes sure you are always raising the reactors to full power and not to single cycles (so multiple following powerdrain-spikes will get A more advanced guide on SR (Set-Reset) Latches and potential applications. Post by joemcguiregaming » Sun Mar 01, 2020 1:20 am. But steam is steam, regardless of temperature, so no priorities:) Consumption was 20 and 80 MW, half of U-235 wasted. A Set-Reset Latch is a circuit network item, that starts emitting a signal when a &quot;set&qu Sep 13, 2019 · I have searched over the requests, and haven't found this one. Top. com. You can wire them to a power switch to isolate your steam engines as long as demand is being met elsewhere. whether the reactor is being fueled or not. Look up how to make an SR latch (aka a memory toggle) with combinators. He posted it on these forums at: this link. I've got a 2x2 reactor array that is fuelled this way with excellent results, a 50MW factory is powered by 480MW installed reactor capacity with zero waste. This throttles the reactors due to fuel starvation and makes the whole system inefficient due to the loss of the neighbour bonus. I still have some solar fields with accus that wouldn't get used if nuclear is running all the time. Since signals are 32-bit integers, we can store up to 32 bits of data per signal: that is either a single 32-bit number, two 16-bit numbers, four 8-bit . - To avoid starvation when only one side of belt it fed I ensured only one of them is used. The SR Latch will identify the Aug 19, 2017 · What you need to implement is a S/R latch, this allows to set condition to turn it on and a condition to turn it off. But there is some middle ground one can work with. The way commonly seen to avoid this issue is to use a SR latch, which provides a cut-in condition and a cut-out condition to make it operate similarly to a household well pump or a home workshop air compressor. The setup is easily expandable as long as you follow the block-like setup (reactors+heatexchangers, tanks, turbines) without any changes to the processing  · Thirdly, you could also automate nuclear reactors with this. Reason: This tutorial needs to be updated due to changes in Factorio 2. It was great for my first creation but I soon realized that its set/reset nature was not very useful in many cases and overall the latch was a little over-designed. So "If PG < 10 2 days ago · Note that you will get less basic resources (Ice, iron, carbon) from this process than if you would use the standard crusher recipes. 7: . I hooked an SR-latch to an accumulator and only turn on the pump when the accumulators run low.  · Aeternus wrote:Simplest solution: A small group of solar collectors to restore power (or a 1.  · First of all, some math (I did it mainly for myself, most results are on wiki) 3 U238 -[kovarex]> 1 U235 1 U235 + 19 U238 -> 10 cells 1 cell -> 200  · Accumulators have the lowest priority. Most Apr 23, 2022 · A simple web app to calculate the ratio of buildings required for a given nuclear reactor layout, saving you effort to make a spreadsheet. use the circuit network to only put 500 iron into the input buffer chest and then use a SR-latch to force the inserters feeding them to turn off and at the same time turn on the inserters that will put the items on the train. g. One of the obvious applications is using this contraption to turn on steam generator reserve when accumulators' energy level is 1% or less, and turn them off  · A Set-Reset Latch is a circuit network item, that starts emitting a signal when a "set" event (logical condition) occurs, and stops emitting the signal only when a "reset" event occurs. What you need to do is to modify the SET and RESET conditions to react to the accumulator charging/discharging, regardless of the actual charge level. These recipes also take longer to execute than the standard versions. If the accumulator falls below a threshold, toggle the engines back on. Search the tags for mining, smelting, and advanced production blueprints. A Set-Reset Latch is a circuit network item, that starts emitting a signal when a "set" event (logical condition) occurs, and stops emitting the signal only when a "reset" event occurs. One of the obvious applications is using this contraption to turn on steam generator reserve when accumulators' energy level is 1% or less, and turn them off Oct 19, 2020 · Using a simple SR latch is the right way to go. latch (n) ELECTRONICS; a circuit that retains whatever output state results from a momentary input Nov 24, 2024 · The circuit uses an RS latch to store the state, whether it's currently waiting for steam levels to rise or to drop, i. Sep 10, 2016 · The standard factorio SR latch is, I think, the one from the "combinators 101" post with two A=0 --> A:1 deciders.  · Nuclear over coal priority; slow switch with hysteresis. This means that other reactors won't receive fuel until another 200 seconds have passed.  · a) A Steam Gauge with SR Latch for hysteresis. Gameplay Help. If I do lose power I most likely will have nuclear plant drop of totally. We want Steam turbines -> Steam engines -> accumulators; In a factory where uranium is low, we want to use nuclear only when absolutely needed (e. But the factorio God that is MadZuri produced what I believe to be the perfect solution. " Aug 19, 2017 · PacifyerGrey wrote:The problem with your setup is the low capacity of accumulators. - Because of fixed latch, does not require priming. This is combined Jun 9, 2022 · In Factorio, you will find an RS latch that is also known as SR latch in several threads in some gaming forums. Place it, connect to grid, put fuel on input belt. Building a smart, automated ammo factory. Quick links. Jan 13, 2024 · I don't use even one SR latch or memory cell, and the only counter I use is a 200 second timer for nuclear reactor fuel control. Introduced in Space Age expansion. a1) An arithmetic combinator to multiply T*12k. Jan 3, 2025 · RS latch - single decider version. Have a latch condition coming from how much a steam tank is filled to enable / disable inserters feeding the fuel in. Nov 10, 2023 · I'd like to +1 the requests to add an R/S and/or S/R latch to the Selector Combinator. solution: above yellow belt loop.  · A Set-Reset Latch is a circuit network item, that starts emitting a signal when a "set" event (logical condition) occurs, and stops emitting the signal only when a "reset" event occurs. Re: When can I (safely) start with nuclear power? Post by JasonCurnow » Thu Feb 25, 2021 1:40 am. This is combined with a timer to only insert one fuel cell every 200 seconds (that's how long a fuel cell lasts). factorio. Another definition is "a mechanism that toggles when an input crosses a threshold, and does not toggle back until crossing a separate threshold. A niche scenario in Vanilla, but could be more important in something like Warptorio or other mods where you have expensive reactor fuel (Space Exploration and its  · Lets say I had installed 160W in coal fed steam engines and 40MW of atomic energy, At the moment base was consuming 100MW, half of max performance. Often, it works on its own if you create the proper mechanical setup, and if something works on a purely mechanical basis, it's a sign that you've done  · A Set-Reset Latch is a circuit network item, that starts emitting a signal when a "set" event (logical condition) occurs, and stops emitting the signal only when a "reset" event occurs. However, when both inputs are true, the latch will reset, so it is  · Factorio Forums. Definition. Nov 9, 2024 · Constant Combinator has what you want, math 50 and 80% of that, use those numbers in the SR latch, though you'd have to do it per item still. As you say with nuclear power steam throughput is different. Smart triggering, counters and sensors, useful circuitry, switching as an art , computers. This way power plant will be online always. Oct 6, 2020 · Accumulators give off a circuit network signal. That's it. A nice Latch section where you define a Set value, a Reset value, and an output signal would make a ton of circuits a lot easier. For example, it is now simple to automate nuclear power production control May 7, 2017 · The SR-latch, giving a setpoint hysteresis, makes sure you are always raising the reactors to full power and not to single cycles (so multiple following powerdrain-spikes will get covered). Oct 8, 2019 · Now, there is 1 normal accumulator and a circuit based SR-latch set to operate between 20 to 90 range. e. 2021 4:11 am Like any nuclear reactor it needs some external power to boot up the inserters, but beyond that, no; it uses no pumps, so it only Apr 4, 2019 · Nuclear power needs power to run - water pumps need power, inserter for uranium fuel cell needs power. However, SR latch will be RS latch as the latch will reset when both inputs are true. But because the interface has some weird priority and it's not an accumulator, power never goes from accumulators to the interface. About A simple calculator for factorio power plant Jul 12, 2016 · It's old diagram and only for personal usage so I used mental shortcuts and there're some errors like output "Each" instead "Each=1" in SR-latch and probably you need one latch per ON/OFF section. I assumed nuclear reactor give me 40MW and coal setup 60MW. And neither do they try to balance their storage capacity. www. 3 days ago · Bitpacking is a way to cram multiple small numbers into a single signal. Will emit T=1 when steam is OK. Help needed on Combinators and RS-Latch. on heavy biter attacks or base pushes where power is Feb 21, 2017 · in lieu of being able to read train contents you'll need a bit of trickery. I have sets of 12 heat exchangers in a row into some tanks, then a pump and then 20 steam engines. Apr 30, 2017 · The latch to insert fuel remains open until fuel is supplied to any one reactor. detect the presence of a train with the rail signals and when one leaves you re Nov 24, 2024 · The circuit uses an RS latch to store the state, whether it's currently waiting for steam levels to rise or to drop, i. Share your designs. This discussion on the Factorio forums starts with the common 2 decider RS latch version, but later a single decider version was proposed. For example switch on when the accumulator drops below 90% A Set-Reset Latch is a circuit network item, that starts emitting a signal when a "set" event (logical condition) occurs, and stops emitting the signal only when a "reset" event occurs.  · set SR latch OFF (Output:) to E>100%. Support. So the whole contraption will emit T=12,000 when Steam level is OK, or nothing if steam is Nov 24, 2024 · Find blueprints for the video game Factorio. Sep 13, 2019 · An SR latch is a mechanism that toggles when an input crosses a threshold, and does not toggle back until crossing a separate threshold. Another Jan 18, 2025 · Find blueprints for the video game Factorio. 2. However, I had a LOT of fun making it and wanted to create better  · A Set-Reset Latch is a circuit network item, that starts emitting a signal when a "set" event (logical condition) occurs, and stops emitting the signal only when a "reset" event occurs. 8MW single boiler duals steam engine chemical power plant, but you'll need to keep a fuel supply stocked for longer blackouts), a small group of batteries, and a S/R latch that disconnects the nuclear powerplant from the main power grid if the batteries fall below a Sep 2, 2022 · Especially with nuclear power coming (damn, covarex is expensive and I need 40 light uranium saved for that) I've been thinking of how to extend this method. if used fuel cell hits the magical limit then empty the bucket (make a train call). The thread goes on to explain why this is better. 0. In the thread, the latch is described as an SR latch. One of the obvious applications is using this contraption to turn on steam generator reserve when accumulators' energy level is 1% or less, and turn them off Jun 1, 2019 · All-Signal SR Latch Memory (SET/4tick, RESET/3tick) This board is to show, discuss and archive useful combinator- and logic-creations. May 15, 2018 · In a factory where a nuclear reactor energy is used, we want to shut down steam engines unless the reactor's steam turbines cannot keep up. nuclear-reactor: 2: power-switch: 1: roboport: 1: decider-combinator: 1: arithmetic-combinator: 1: accumulator: Have SR Latch power system so it prioritize solar and accumulator first. Now is has a huge steam storage capacity that Oct 6, 2020 · I'm working with 32 bit so i can't speak for nuclear, but it will produce first with Solar, then Steam, and lastly, Accumulators, meaning that even at night steam will produce electricity first, even if your accumulators are at maximum. Use (google it if you need to) a SR Latch to set a separate point for steam power to shut off if desired May 6, 2017 · That alone is insufficient though, as the switch will bounce rapidly at the setpoint and make some obnoxious effects in doing so. bwuply qakfy jjukrg lcqdnl auxn puo rokc hsxrafqb kkbymyg kugy